In Vivo Testing of an Infection-Resistant Vascular Graft Material

Present prosthetic arterial conduits continue to suffer the clinically and economically catastrophic complication of infection. We recently described a novel technique for binding quinolone antibiotics to Dacron based on principles of textile chemistry. This thermofixation procedure ("pad/heat&...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of surgical research 1993-11, Vol.55 (5), p.543-547
Hauptverfasser: Ozaki, C.Keith, Phaneuf, Matthew D., Bide, Martin J., Quist, William C., Alessi, Jean M., LoGerfo, Frank W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Present prosthetic arterial conduits continue to suffer the clinically and economically catastrophic complication of infection. We recently described a novel technique for binding quinolone antibiotics to Dacron based on principles of textile chemistry. This thermofixation procedure ("pad/heat") utilizes the limited fibrophilic characteristics of the quinolone antibiotic ciprofloxacin (Cipro) to permit pad/heat application and allowed controlled, sustained release from Dacron in several in vitro assays. The objective of this study was to test this infection-resistant prosthetic vascular graft material in an in vivo model. Dacron segments (1 cm2, either plain, dipped into antibiotic immediately prior to implantation, or Cipro pad/heat treated) were implanted in the dorsal subcutaneous tissue of the rabbit and directly contaminated with 106Staphylococcus aureus. After 1 week, the samples were sterily harvested. Wounds were blindly graded on a scale from 1 (no evidence of infection, good tissue incorporation) to 4 (suppurative infection extending outside of the graft pocket, no gross tissue incorporation). Plain Dacron was easily infected in this model (mean grade 3.1 ± 0.6, 92% culture positive). Notably, however, a significant (P < 0.05) wound grade difference between the dipped (2.3 ± 1.0) and pad/heat (1.4 ± 0.6) samples was demonstrated. Determination of adherent bacteria present on the implanted Dacron pieces by sonication and culture studies again revealed a significant difference between the dipped (56% culture positive) and pad/heat (12% culture) groups (P < 0.025). Histologic studies confirmed good tissue incorporation of the pad/heat samples. This project opens new avenues in the development of infection-resistant biomaterials.
ISSN:0022-4804
1095-8673
DOI:10.1006/jsre.1993.1181