Severe combined respiratory and myocardial failure treated with high-frequency ventilation
High levels of positive end-expiratory pressure (PEEP) impair cardiac output. The subsequent lowering of mixed venous oxygenation, when coupled with a significant intrapulmonary shunt, may dramatically depress Pao2. We present a patient whose severe myocardial and respiratory insufficiency was unman...
Gespeichert in:
Veröffentlicht in: | Critical care medicine 1985-03, Vol.13 (3), p.208-209 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | High levels of positive end-expiratory pressure (PEEP) impair cardiac output. The subsequent lowering of mixed venous oxygenation, when coupled with a significant intrapulmonary shunt, may dramatically depress Pao2. We present a patient whose severe myocardial and respiratory insufficiency was unmanageable on conventional ventilation with high levels of PEEP and maximal inotropic support. High-frequency ventilation superimposed on conventional ventilation lowered peak airway pressure and dramatically improved both cardiac and pulmonary function. |
---|---|