A Comparison of the Strength and Stability of Six Techniques of Cerclage Wire Fixation for Fractures
An in vitro comparison of six methods of cerclage wire fixation was performed using 1-mm-diameter stainless steel wire. A testing apparatus was designed to simulate the tensile forces on a cerclage wire around a femoral shaft fracture. The hairpin cerclage knot that we describe generated significant...
Gespeichert in:
Veröffentlicht in: | Journal of orthopaedic trauma 1993, Vol.7 (3), p.221-225 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An in vitro comparison of six methods of cerclage wire fixation was performed using 1-mm-diameter stainless steel wire. A testing apparatus was designed to simulate the tensile forces on a cerclage wire around a femoral shaft fracture. The hairpin cerclage knot that we describe generated significantly higher initial compressive force (p |
---|---|