Measurement of the mechanical stiffness in cyclotorsion of the human eye

We have measured the stiffness in cyclotorsion of the human eye using a scleral suction contact ring mounted on a shaft fitted with an eddy current motor to provide the torque to turn the eye and a shaft-position-encoder to register the torsion. The relation proved to be almost linear within the mea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Vision research (Oxford) 1984, Vol.24 (9), p.961-967
Hauptverfasser: Simonsz, Huibert J., Crone, Robert A., de Waal, Bob J., Schooneman, Martin, Lorentz de Haas, Hendrik A.L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have measured the stiffness in cyclotorsion of the human eye using a scleral suction contact ring mounted on a shaft fitted with an eddy current motor to provide the torque to turn the eye and a shaft-position-encoder to register the torsion. The relation proved to be almost linear within the measuring range in four subjects with constant slope values of about 0.75, 0.60, 0.55 and 0.45 g·cm/deg. The average, 0.6 g·cm/deg, equals 0.5 g if applied at the radius of the globe. This value is rather low compared to the values obtained by other authors for horizontal eye movements. This may be due to different length-tension characteristics of oblique muscles compared to recti muscles.
ISSN:0042-6989
1878-5646