Robot-Assisted Partial Nephrectomy: An International Experience

Abstract Background Robot-assisted partial nephrectomy (RAPN) is emerging as a viable approach for nephron-sparing surgery (NSS), though many reports to date have been limited by evaluation of a relatively small number of patients. Objective We present the largest multicenter RAPN experience to date...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European urology 2010-05, Vol.57 (5), p.815-820
Hauptverfasser: Benway, Brian M, Bhayani, Sam B, Rogers, Craig G, Porter, James R, Buffi, Nicolò M, Figenshau, Robert S, Mottrie, Alexandre
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Robot-assisted partial nephrectomy (RAPN) is emerging as a viable approach for nephron-sparing surgery (NSS), though many reports to date have been limited by evaluation of a relatively small number of patients. Objective We present the largest multicenter RAPN experience to date, culling data from four high-volume centers, with focus upon functional and oncologic outcomes. Design, setting, and participants A retrospective chart review was performed for 183 patients who underwent RAPN at four centers between 2006 and 2008. Surgical procedure RAPN was performed using methods outlined in the supplemental video material. Though operative technique was similar across all institutions, there were minor variations in trocar placement and hilar control. Measurements Perioperative parameters, including operative time, warm ischemic time, blood loss, and perioperative complications were recorded. In addition, we reviewed functional and oncologic outcomes. Results and limitations Mean age at treatment was 59.3 yr. Mean tumor size was 2.87 cm. Mean total operative time was 210 min while mean ischemic time was 23.9 min. Calyceal repair was required in 52.1% of procedures. Mean estimated blood loss was 131.5 ml. Sixty-nine percent of excised tumors were malignant, of which 2.7% exhibited positive surgical margins. The incidence of major complications was 8.2%. At up to 26 mo follow-up, there have been no documented recurrences and no significant change in serum creatinine (1.03 vs 1.04 mg/dl, p = 0.84) or estimated glomerular filtration rate (eGFR) from baseline (82.2 vs 79.4 mg/ml per square meter, p = 0.74). The study is limited by its retrospective nature, and the outcomes are likely influenced by the robust prior laparoscopic renal experience of each of the surgeons included in this study. Conclusions RAPN is a safe and efficacious approach for NSS, offering short ischemic times, as well as perioperative morbidity equivalent to other standard approaches. Moreover, RAPN is capable of providing patients with excellent functional and oncologic outcomes.
ISSN:0302-2838
1873-7560
DOI:10.1016/j.eururo.2010.01.011