Observation of the Posterior Endothelial Surface of the Rabbit Cornea Using Atomic Force Microscopy
PURPOSETo study the surface of normal corneal endothelium by means of atomic force microscopy (AFM). METHODSThe central corneal endothelial posterior surface of New Zealand white rabbits was examined. Specimens were observed in Balanced Salt Solution using the contact mode of the AFM either fresh or...
Gespeichert in:
Veröffentlicht in: | Cornea 2003-10, Vol.22 (7), p.651-664 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | PURPOSETo study the surface of normal corneal endothelium by means of atomic force microscopy (AFM).
METHODSThe central corneal endothelial posterior surface of New Zealand white rabbits was examined. Specimens were observed in Balanced Salt Solution using the contact mode of the AFM either fresh or after fixation in cacodylate-buffered glutaraldehyde solution. Removal of sialic acid residues and hyaluronic acid was achieved by means of enzymatic treatment with neuraminidase and hyaluronidase.
RESULTSObservation of the fresh specimens revealed the presence of an apical endothelial surface coating material (glycocalyx). Removal of sialic acid residues and hyaluronic acid after enzymatic treatment using neuraminidase and hyaluronidase, respectively, permitted the elucidation of the structure of the nondigested coating material. Fixation of the samples resulted in removal of the surface coating material. The imaging of the fixed endothelium surface revealed the mosaic of polygonal cells with the apical flaps of cell junctions emerging over the cell surface. The cell shape and the other characteristics of the posterior surface fixed endothelium were comparable to those described in the literature using scanning electron microscopy. The scanning of very small ranges has provided high-resolution images at the nanometer level in fixed and fresh corneal endothelial surfaces.
CONCLUSIONThe atomic force microscope represents a new powerful imaging tool permitting high-resolution observation of corneal endothelium surface in fresh and minimally prepared fixed specimens. |
---|---|
ISSN: | 0277-3740 1536-4798 |
DOI: | 10.1097/00003226-200310000-00009 |