Intraocular Pressure and Retinal Vascular Changes During Transient Exposure to Microgravity

We measured intraocular pressures and retinal vascular diameters from 11 subjects during 20 seconds of microgravity produced by parabolic flight on board a KC-135 aircraft. Intraocular pressures increased 58% during parabolic flight compared to baseline values (19 ± 1 mm Hg vs 12 ± 1 mm Hg, respecti...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of ophthalmology 1993-03, Vol.115 (3), p.347-350
Hauptverfasser: Mader, COL. Thomas H., Gibson, C. Robert, Caputo, Michael, Hunter, Norwood, Taylor, Gerald, Charles, John, Meehan, Richard T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We measured intraocular pressures and retinal vascular diameters from 11 subjects during 20 seconds of microgravity produced by parabolic flight on board a KC-135 aircraft. Intraocular pressures increased 58% during parabolic flight compared to baseline values (19 ± 1 mm Hg vs 12 ± 1 mm Hg, respectively; P < .001). A 4% reduction in the caliber of retinal arteries was also noted during microgravity, but this change did not achieve statistical significance (7.8 ± 0.3 pixels at zerogravity vs 8.1 ± 0.3 pixels at 1g; P = .07). The increase in intraocular pressure and trend of arteries to constrict are thought to result from cephalad shifts in intravascular and extravascular body fluids as a result of the absence of the 1g hydrostatic gradient. The results of our study confirm that this fluid shift and its effects on the eye occur rapidly, within 20 seconds of exposure to microgravity.
ISSN:0002-9394
1879-1891
DOI:10.1016/S0002-9394(14)73586-X