Two new methods of tendon repair: An in vitro evaluation of tensile strength and gap formation
A new tendon repair design incorporating a mesh sleeve was, together with a new epitendinal suture technique (cross-stitch), tested biomechanically on sheep tendons. The mean breaking strength with a 6-0 suture was 103 N for the mesh sleeve repair and 63 N for the cross-stitch alone, both significan...
Gespeichert in:
Veröffentlicht in: | The Journal of hand surgery (American ed.) 1993, Vol.18 (1), p.58-65 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A new tendon repair design incorporating a mesh sleeve was, together with a new epitendinal suture technique (cross-stitch), tested biomechanically on sheep tendons. The mean breaking strength with a 6-0 suture was 103 N for the mesh sleeve repair and 63 N for the cross-stitch alone, both significantly greater than the 48 N recorded for the modified Kessler repair performed with a 4-0 polyester suture and reinforced with a circumferential conventional 6-0 epitendinal stitch. The cross-stitch grasp was 117% stronger than the conventional epitendinal grasp reinforced by a core stitch. The new techniques effectively prevented the large gaps that occurred in the modified Kessler repair. |
---|---|
ISSN: | 0363-5023 1531-6564 |
DOI: | 10.1016/0363-5023(93)90246-Y |