On-blaze operation of a Mo/Si multilayer-coated, concave diffraction grating in the 136-142-Å wavelength region and near normal incidence

The efficiency and resolving power of a concave, 2400-groove/mm, blazed diffraction grating that had a Mo/Si multilayer coating were determined. The multilayer coating had a peak reflectance of 55% at 140-A near normal incidence. The efficiency of the multilayer grating for wavelengths in the 136-13...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Optics 1993-09, Vol.32 (25), p.4890-4897
Hauptverfasser: SEELY, J. F, KOWALSKI, M. P, HUNTER, W. R, RIFE, J. C, BARBEE, T. W, HOLLAND, G. E, BOYER, C. N, BROWN, C. M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The efficiency and resolving power of a concave, 2400-groove/mm, blazed diffraction grating that had a Mo/Si multilayer coating were determined. The multilayer coating had a peak reflectance of 55% at 140-A near normal incidence. The efficiency of the multilayer grating for wavelengths in the 136-139-A range was 2% near normal incidence. This efficiency was a factor of 150 greater than the efficiency of a sister replica Au-coated grating in the same wavelength region. The resolving power of the multilayercoated grating in the third order of a V viii transition with a first-order wavelength of 140.451 A was 9100. Comparisons with the Au-coated grating indicated that the application of the multilayer coating did not affect the resolving power or the blaze angle.
ISSN:0003-6935
1559-128X
1539-4522
DOI:10.1364/AO.32.004890