The development and evaluation of microstructured reactors for the water gas shift and preferential oxidation reactions in the 5 kW range
5 kW el One-Stage Water Gas Shift (WGS) and Preferential Oxidation (PROx) reactors were designed and evaluated for the clean-up of surrogate diesel reformate. For the WGS reactor, CO conversions of up to 95% were attained using typical surrogate synthetic diesel reformate. The PROx reactor was capab...
Gespeichert in:
Veröffentlicht in: | International journal of hydrogen energy 2010-03, Vol.35 (6), p.2317-2327 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 5
kW
el One-Stage Water Gas Shift (WGS) and Preferential Oxidation (PROx) reactors were designed and evaluated for the clean-up of surrogate diesel reformate. For the WGS reactor, CO conversions of up to 95% were attained using typical surrogate synthetic diesel reformate. The PROx reactor was capable of converting a feed concentration of 1.0
mol% CO to 20
ppm. Load changes for both reactors could be carried out without significant overshoots of carbon monoxide. |
---|---|
ISSN: | 0360-3199 1879-3487 |
DOI: | 10.1016/j.ijhydene.2009.12.113 |