Design of Multipulse Power Supply for Small Pulsed High Magnetic Field Device
Three small pulsed high magnet field devices (SPHMF) which can continuously operate 20 times in rated power with different maximum magnetic field intensity from 10 T~40 T were developed in Wuhan High Magnet Field Center(WHMFC). The SPHMF systems are used to investigate the sterilization of fruit jui...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2010-06, Vol.20 (3), p.1689-1692 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Three small pulsed high magnet field devices (SPHMF) which can continuously operate 20 times in rated power with different maximum magnetic field intensity from 10 T~40 T were developed in Wuhan High Magnet Field Center(WHMFC). The SPHMF systems are used to investigate the sterilization of fruit juice, magnetization of permanent magnet for wind power generator, some industrial applications and so on. The SPHMF consists of pulsed capacitor power supply, charger, control & measurement system, cryogenic system and pulsed magnet. These systems can accommodate sample room size from ¿12 mm to ¿18 mm and hold sample room in indoor temperature 300 K for different scientific researches and high magnetic field industrial applications. In this paper, power supply, magnet, control system and cryogenic system are presented. The total experiment results of SPHMF show that the devices are feasible, steady and reliable. |
---|---|
ISSN: | 1051-8223 1558-2515 |
DOI: | 10.1109/TASC.2009.2039562 |