Lactate Biosensor Based on Hydrotalcite-Like Compounds: Performances and Application to Serum Samples
A lactate biosensor based on lactate oxidase supported onto a hydrotalcite, electrochemically deposited on a platinum surface, was developed for the first time. For the best electrode configuration, a linear response up to 0.8 mM, with a limit of detection of 14 μM and a sensitivity of 91 mA M−1 cm−...
Gespeichert in:
Veröffentlicht in: | Electroanalysis (New York, N.Y.) N.Y.), 2009-11, Vol.21 (22), p.2401-2409 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A lactate biosensor based on lactate oxidase supported onto a hydrotalcite, electrochemically deposited on a platinum surface, was developed for the first time. For the best electrode configuration, a linear response up to 0.8 mM, with a limit of detection of 14 μM and a sensitivity of 91 mA M−1 cm−2, was obtained. The influence of some interferents due to the oxidation of hydrogen peroxide (at +0.35 V vs. SCE) was also studied. By controlling carefully the experimental conditions, the determination of lactate in a commercial serum sample in the presence of interferents was successfully accomplished. |
---|---|
ISSN: | 1040-0397 1521-4109 |
DOI: | 10.1002/elan.200900118 |