An Assessment of the Corning Electrophoretic Procedure for High Density Lipoprotein Cholesterol Estimation

The electrophoretic procedure for high density lipoprotein cholesterol determination recently introduced by Corning Medical has been assessed. The results correlated well with those obtained by phosphotungstate/Mg precipitation and ultracentrifuge procedures, but the between-batch CV was 6% in the c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of clinical biochemistry 1980-05, Vol.17 (3), p.148-152
Hauptverfasser: Bullock, D G, Carter, T J N, Cosgrove, Carmel M, Hughes, Susan V
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 152
container_issue 3
container_start_page 148
container_title Annals of clinical biochemistry
container_volume 17
creator Bullock, D G
Carter, T J N
Cosgrove, Carmel M
Hughes, Susan V
description The electrophoretic procedure for high density lipoprotein cholesterol determination recently introduced by Corning Medical has been assessed. The results correlated well with those obtained by phosphotungstate/Mg precipitation and ultracentrifuge procedures, but the between-batch CV was 6% in the clinically important range below 1 mmol/l. The densitometer, which must be carefully aligned before use for this analysis, seemed sensitive to variations in the plates and patterns produced. The technique required great care, especially with timing, and appeared expensive.
doi_str_mv 10.1177/000456328001700309
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_75226332</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_000456328001700309</sage_id><sourcerecordid>75226332</sourcerecordid><originalsourceid>FETCH-LOGICAL-c382t-79ea50f2b42434caf32727c8ea60b047ac00b79cb0f4a34ef04599c13f6bfe993</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMotX78AUHIydvqbJJudo-l1g8o6EHPSzadtCnbpCbZg__elBYvgqdhZp55eecl5KaE-7KU8gEAxKTirAYoJQCH5oSMSzmpizJPTsl4DxR74pxcxLjJLcvciIykgErwekw2U0enMWKMW3SJekPTGunMB2fdis571Cn43doHTFbT9-A1LoeA1PhAX-xqTR_RRZu-6cLu_C74hNbR2dr3GBMG39N5THarkvXuipwZ1Ue8PtZL8vk0_5i9FIu359fZdFFoXrNUyAbVBAzrBBNcaGU4k0zqGlUFHQipNEAnG92BEYoLNDmDptElN1VnsGn4Jbk76GY7X0P20W5t1Nj3yqEfYisnjFWcswyyA6iDjzGgaXchew3fbQntPuD2b8D56PaoPnRbXP6eHBPN-4fDPqoVths_BJef_U_xB3K1hDY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>75226332</pqid></control><display><type>article</type><title>An Assessment of the Corning Electrophoretic Procedure for High Density Lipoprotein Cholesterol Estimation</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Bullock, D G ; Carter, T J N ; Cosgrove, Carmel M ; Hughes, Susan V</creator><creatorcontrib>Bullock, D G ; Carter, T J N ; Cosgrove, Carmel M ; Hughes, Susan V</creatorcontrib><description>The electrophoretic procedure for high density lipoprotein cholesterol determination recently introduced by Corning Medical has been assessed. The results correlated well with those obtained by phosphotungstate/Mg precipitation and ultracentrifuge procedures, but the between-batch CV was 6% in the clinically important range below 1 mmol/l. The densitometer, which must be carefully aligned before use for this analysis, seemed sensitive to variations in the plates and patterns produced. The technique required great care, especially with timing, and appeared expensive.</description><identifier>ISSN: 0004-5632</identifier><identifier>EISSN: 1758-1001</identifier><identifier>DOI: 10.1177/000456328001700309</identifier><identifier>PMID: 7406438</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Chemical Precipitation ; Cholesterol - blood ; Densitometry ; Electrophoresis, Agar Gel - methods ; Humans ; Lipoproteins, HDL - blood ; Reagent Kits, Diagnostic - standards ; Ultracentrifugation</subject><ispartof>Annals of clinical biochemistry, 1980-05, Vol.17 (3), p.148-152</ispartof><rights>1980 Association for Clinical Biochemistry</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c382t-79ea50f2b42434caf32727c8ea60b047ac00b79cb0f4a34ef04599c13f6bfe993</citedby><cites>FETCH-LOGICAL-c382t-79ea50f2b42434caf32727c8ea60b047ac00b79cb0f4a34ef04599c13f6bfe993</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7406438$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bullock, D G</creatorcontrib><creatorcontrib>Carter, T J N</creatorcontrib><creatorcontrib>Cosgrove, Carmel M</creatorcontrib><creatorcontrib>Hughes, Susan V</creatorcontrib><title>An Assessment of the Corning Electrophoretic Procedure for High Density Lipoprotein Cholesterol Estimation</title><title>Annals of clinical biochemistry</title><addtitle>Ann Clin Biochem</addtitle><description>The electrophoretic procedure for high density lipoprotein cholesterol determination recently introduced by Corning Medical has been assessed. The results correlated well with those obtained by phosphotungstate/Mg precipitation and ultracentrifuge procedures, but the between-batch CV was 6% in the clinically important range below 1 mmol/l. The densitometer, which must be carefully aligned before use for this analysis, seemed sensitive to variations in the plates and patterns produced. The technique required great care, especially with timing, and appeared expensive.</description><subject>Chemical Precipitation</subject><subject>Cholesterol - blood</subject><subject>Densitometry</subject><subject>Electrophoresis, Agar Gel - methods</subject><subject>Humans</subject><subject>Lipoproteins, HDL - blood</subject><subject>Reagent Kits, Diagnostic - standards</subject><subject>Ultracentrifugation</subject><issn>0004-5632</issn><issn>1758-1001</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1980</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1LAzEQhoMotX78AUHIydvqbJJudo-l1g8o6EHPSzadtCnbpCbZg__elBYvgqdhZp55eecl5KaE-7KU8gEAxKTirAYoJQCH5oSMSzmpizJPTsl4DxR74pxcxLjJLcvciIykgErwekw2U0enMWKMW3SJekPTGunMB2fdis571Cn43doHTFbT9-A1LoeA1PhAX-xqTR_RRZu-6cLu_C74hNbR2dr3GBMG39N5THarkvXuipwZ1Ue8PtZL8vk0_5i9FIu359fZdFFoXrNUyAbVBAzrBBNcaGU4k0zqGlUFHQipNEAnG92BEYoLNDmDptElN1VnsGn4Jbk76GY7X0P20W5t1Nj3yqEfYisnjFWcswyyA6iDjzGgaXchew3fbQntPuD2b8D56PaoPnRbXP6eHBPN-4fDPqoVths_BJef_U_xB3K1hDY</recordid><startdate>198005</startdate><enddate>198005</enddate><creator>Bullock, D G</creator><creator>Carter, T J N</creator><creator>Cosgrove, Carmel M</creator><creator>Hughes, Susan V</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198005</creationdate><title>An Assessment of the Corning Electrophoretic Procedure for High Density Lipoprotein Cholesterol Estimation</title><author>Bullock, D G ; Carter, T J N ; Cosgrove, Carmel M ; Hughes, Susan V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c382t-79ea50f2b42434caf32727c8ea60b047ac00b79cb0f4a34ef04599c13f6bfe993</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1980</creationdate><topic>Chemical Precipitation</topic><topic>Cholesterol - blood</topic><topic>Densitometry</topic><topic>Electrophoresis, Agar Gel - methods</topic><topic>Humans</topic><topic>Lipoproteins, HDL - blood</topic><topic>Reagent Kits, Diagnostic - standards</topic><topic>Ultracentrifugation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bullock, D G</creatorcontrib><creatorcontrib>Carter, T J N</creatorcontrib><creatorcontrib>Cosgrove, Carmel M</creatorcontrib><creatorcontrib>Hughes, Susan V</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Annals of clinical biochemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bullock, D G</au><au>Carter, T J N</au><au>Cosgrove, Carmel M</au><au>Hughes, Susan V</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An Assessment of the Corning Electrophoretic Procedure for High Density Lipoprotein Cholesterol Estimation</atitle><jtitle>Annals of clinical biochemistry</jtitle><addtitle>Ann Clin Biochem</addtitle><date>1980-05</date><risdate>1980</risdate><volume>17</volume><issue>3</issue><spage>148</spage><epage>152</epage><pages>148-152</pages><issn>0004-5632</issn><eissn>1758-1001</eissn><abstract>The electrophoretic procedure for high density lipoprotein cholesterol determination recently introduced by Corning Medical has been assessed. The results correlated well with those obtained by phosphotungstate/Mg precipitation and ultracentrifuge procedures, but the between-batch CV was 6% in the clinically important range below 1 mmol/l. The densitometer, which must be carefully aligned before use for this analysis, seemed sensitive to variations in the plates and patterns produced. The technique required great care, especially with timing, and appeared expensive.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>7406438</pmid><doi>10.1177/000456328001700309</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0004-5632
ispartof Annals of clinical biochemistry, 1980-05, Vol.17 (3), p.148-152
issn 0004-5632
1758-1001
language eng
recordid cdi_proquest_miscellaneous_75226332
source MEDLINE; Alma/SFX Local Collection
subjects Chemical Precipitation
Cholesterol - blood
Densitometry
Electrophoresis, Agar Gel - methods
Humans
Lipoproteins, HDL - blood
Reagent Kits, Diagnostic - standards
Ultracentrifugation
title An Assessment of the Corning Electrophoretic Procedure for High Density Lipoprotein Cholesterol Estimation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T07%3A45%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20Assessment%20of%20the%20Corning%20Electrophoretic%20Procedure%20for%20High%20Density%20Lipoprotein%20Cholesterol%20Estimation&rft.jtitle=Annals%20of%20clinical%20biochemistry&rft.au=Bullock,%20D%20G&rft.date=1980-05&rft.volume=17&rft.issue=3&rft.spage=148&rft.epage=152&rft.pages=148-152&rft.issn=0004-5632&rft.eissn=1758-1001&rft_id=info:doi/10.1177/000456328001700309&rft_dat=%3Cproquest_cross%3E75226332%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=75226332&rft_id=info:pmid/7406438&rft_sage_id=10.1177_000456328001700309&rfr_iscdi=true