A comparison of methods of blood withdrawal and sample preparation for potassium measurements

The effect on measured potassium values of a number of factors involved in sample acquisition and preparation were investigated. Measured potassium values in either plasma or serum were not influenced by the site of sample withdrawal, the presence of a tourniquet, or the time elapsed between blood s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Anesthesiology (Philadelphia) 1980-07, Vol.53 (1), p.60-63
Hauptverfasser: Hill, A B, Nahrwold, M L, Noonan, D, Northrop, P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The effect on measured potassium values of a number of factors involved in sample acquisition and preparation were investigated. Measured potassium values in either plasma or serum were not influenced by the site of sample withdrawal, the presence of a tourniquet, or the time elapsed between blood sampling and analysis. However, increasing heparin concentrations and/or volumes decreased potassium values. The highest values were obtained in samples obtained in a syringe that had been washed with minimum volumes of heparin. It is concluded that this common clinical practice is based on a sound scientific rationale.
ISSN:0003-3022
DOI:10.1097/00000542-198007000-00012