Effect of Particle Size on Ophthalmic Bioavailability of Dexamethasone Suspensions in Rabbits
Three suspensions of 0.1% [3H]dexamethasone were prepared with mean particle sizes of 5.75, 11.5, and 22.0 μm. The suspensions were dosed topically to the right eyes of rabbits. Their bioavailability was compared by measuring aqueous humor and corneal levels over 5hr. A statistically significant ran...
Gespeichert in:
Veröffentlicht in: | Journal of pharmaceutical sciences 1980-04, Vol.69 (4), p.391-394 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Three suspensions of 0.1% [3H]dexamethasone were prepared with mean particle sizes of 5.75, 11.5, and 22.0 μm. The suspensions were dosed topically to the right eyes of rabbits. Their bioavailability was compared by measuring aqueous humor and corneal levels over 5hr. A statistically significant rank-order correlation was observed between increasing drug levels and decreasing particle size. |
---|---|
ISSN: | 0022-3549 1520-6017 |
DOI: | 10.1002/jps.2600690407 |