AMNIOTIC FLUID OPTICAL DENSITY AND NEONATAL RESPIRATORY OUTCOME
A simple, rapid, economical, and accurate test to assess fetal pulmonary maturity on a 24-hour basis, 7 days a week, is urgently needed. A 15-minute test has been developed that correlates well with fetal pulmonary maturity.Optical dinsity (OD) readings at 650 nm of ≥ 0.15 in pigment-free, centrifug...
Gespeichert in:
Veröffentlicht in: | Obstetrics and gynecology (New York. 1953) 1980-02, Vol.55 (2), p.262-264 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A simple, rapid, economical, and accurate test to assess fetal pulmonary maturity on a 24-hour basis, 7 days a week, is urgently needed. A 15-minute test has been developed that correlates well with fetal pulmonary maturity.Optical dinsity (OD) readings at 650 nm of ≥ 0.15 in pigment-free, centrifuged (2000 xg, 10 minutes) amniotic fluids obtained from gestations of 33 to 42 weeks correlate with fetal pulmonary maturity (131 of 131, 100%). When OD readings are < 0.15 in fluids from gestations of 24 to 40 weeks, and antepartum steroids are utilized, the incidence of respiratory distress syndrome (RDS) s 8.3% (14 of 169). The true false-negative rate in this group is therfore unknown. |
---|---|