Efficacy of Ultrasonic versus Laser-activated Irrigation to Remove Artificially Placed Dentin Debris Plugs

Abstract Introduction The study assessed the efficacy of laser activated irrigation (LAI) with Erbium: Yttrium Aluminum Garnet (Er:YAG) and Erbium Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) wavelengths as compared with passive ultrasonic irrigation (PUI). Previously proposed irrigation t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of endodontics 2010-09, Vol.36 (9), p.1580-1583
Hauptverfasser: De Moor, Roeland J.G., DDS, MSc, PhD, Meire, Maarten, DDS, MSc, Goharkhay, Kawe, DMD, MD, Moritz, Andreas, DMD, DM, PhD, Vanobbergen, Jacques, DDS, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Introduction The study assessed the efficacy of laser activated irrigation (LAI) with Erbium: Yttrium Aluminum Garnet (Er:YAG) and Erbium Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) wavelengths as compared with passive ultrasonic irrigation (PUI). Previously proposed irrigation times were used for LAI (4× 5 seconds) and the intermittent flush technique (3× 20 seconds). Methods We used a split root model with an artificial root canal wall groove. Roots were prepared to an apical size # 40 with ProFiles 0.06 (Dentsply Maillefer, Baillaigues, Switzerland). Five groups of 20 straight canine roots were evaluated as follows: Group 1: hand irrigation for 20 s with 2.5% NaOCl (CI); Group 2: PUI performed once for 20 s with the #20 Irrisafe (Satelec Acteon group, Merignac, France) (PUI 1); Group 3: PUI for 3x 20 s with the Irrisafe (PUI 2); Group 4: LAI with the Er,Cr:YSGG laser and Z2 (200 μm) Endolase tip (Biolase, San Clemente, USA) at 75 mJ for 4x 5 s (LAI 1); Group 5: LAI with the Er:YAG laser (HoYa Versawave, Cortaboeuf, France) and a 200 μm endodontic fiber at 75 mJ for 4x 5 s (LAI 2). Images from the groove were taken before and after irrigation. The quantity of dentin debris in the groove after the experimental protocols was evaluated. Results Statistically significant differences (p < 0.05) were found between CI and all other groups and between PUI 1 and the other groups. Conclusion LAI techniques using erbium lasers (Er:YAG or Er,Cr:YSGG) for 20 seconds (4× 5 seconds) are as efficient as PUI with the intermittent flush technique (3× 20 seconds).
ISSN:0099-2399