Effective bowel cleansing before colonoscopy: a randomized study of split-dosage versus non-split dosage regimens of high-volume versus low-volume polyethylene glycol solutions

Background Adequate bowel cleansing is essential for a high-quality, effective, and safe colonoscopy. Objectives To evaluate the degree of colon cleansing comparing split-dosage versus non-split-dosage intake of two different polyethylene glycol (PEG) volumes (low-volume PEG + ascorbic acid vs stand...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastrointestinal endoscopy 2010-08, Vol.72 (2), p.313-320
Hauptverfasser: Marmo, Riccardo, MD, Rotondano, Gianluca, MD, FASGE, FACG, Riccio, Giovanni, MD, Marone, Armando, MD, Bianco, Maria Antonia, MD, Stroppa, Italo, MD, Caruso, Anna, MD, Pandolfo, Nicola, MD, Sansone, Stefano, MD, Gregorio, Elena, RN, D'Alvano, Giuseppe, RN, Procaccio, Nicoletta, RN, Capo, Pina, RN, Marmo, Clelia, MS, Cipolletta, Livio, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Adequate bowel cleansing is essential for a high-quality, effective, and safe colonoscopy. Objectives To evaluate the degree of colon cleansing comparing split-dosage versus non-split-dosage intake of two different polyethylene glycol (PEG) volumes (low-volume PEG + ascorbic acid vs standard-volume PEG-electrolyte solution) and to identify predictors of poor bowel cleansing. Design Single-blind, active control, randomized study. Setting Tertiary-care institutions in Italy. Patients This study involved adult patients undergoing elective colonoscopy. Intervention Colonoscopy with different bowel preparation methods. Main Outcome Measurements Degree of bowel cleansing. Results We randomized 895 patients, and 868 patients were finally included in intention-to-treat (ITT) analysis. Overall compliance was excellent (97%) for both preparation methods. No difference in tolerability was recorded. Palatability was superior with low volume compared with high volume (acceptable or good 58% vs 51%, respectively, P < .005), independently of intake schedule. PEG plus ascorbic acid produced the same degree of cleansing as standard-volume PEG-electrolyte solution (77% vs 73.4%, respectively, within the split-dosage group and 41.7% vs 44.3%, respectively, within the non-split-dosage group). Independently of PEG volumes, the split-dosage regimen produced markedly superior cleansing results over the same-day method (good/excellent 327/435, 75.2% vs 186/433, 43.0%, P = .00001). Maximum cleansing was observed in colonoscopies performed within 8 hours from the last fluid intake versus over 8 hours from the last fluid intake ( P < .001). The degree of bowel cleansing affected both cecal intubation (failed intubation 11.7% with fair/poor preparation vs 1.2% with good/excellent preparation, P = .00001) and polyp detection rates (12.2% with fair/poor vs 24.6% with good/excellent preparation, P = .001). Aborted procedures were significantly more frequent in the non-split-dosage arm (21.2% vs 6.9%, odds ratio [OR] 3.60 [2.29-5.77], P < .0001). Independent predictors of poor bowel cleansing were male sex (OR 1.45 [1.08-1.96], P = .014) and a non-split-dosage bowel preparation schedule (OR 2.08 [1.89-2.37], P = .0001). Conclusion Low-volume PEG plus ascorbic acid is as effective as high-volume PEG-electrolyte solution but has superior palatability. A split-dosage schedule is the most effective bowel cleansing method. Colonoscopy should be performed within 8 hours of the last
ISSN:0016-5107
1097-6779