The diagnostic accuracy of 256-row computed tomographic angiography compared with invasive coronary angiography in patients with suspected coronary artery disease

Aims To assess the diagnostic accuracy of 256-row computed tomographic angiography (CTA) in patients with suspected coronary artery disease (CAD). Non-invasive imaging of the coronary artery by CTA has increasingly been used in recent years. The accuracy of 256-row CTA has not yet been studied. We s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European heart journal 2010-08, Vol.31 (15), p.1916-1923
Hauptverfasser: Chao, Shu-Ping, Law, Wai-Yip, Kuo, Chu-Jen, Hung, Huei-Fong, Cheng, Jun-Jack, Lo, Huey-Ming, Shyu, Kou-Gi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Aims To assess the diagnostic accuracy of 256-row computed tomographic angiography (CTA) in patients with suspected coronary artery disease (CAD). Non-invasive imaging of the coronary artery by CTA has increasingly been used in recent years. The accuracy of 256-row CTA has not yet been studied. We sought to assess the accuracy of 256-row CTA compared with invasive coronary angiography (ICA) in the diagnosis and assessment of CAD. Methods and results We prospectively evaluated 104 consecutive individuals who accepted CTA and then underwent ICA. The presence of stenosis ≥50% was considered obstructive. The diagnostic accuracy of CTA for detecting obstructive stenosis was compared with that of ICA. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate the diagnostic accuracy of CTA relative to ICA. A total of 86 patients had obstructive CAD. The patient-based analysis of CTA for detecting stenosis ≥50% according to ICA revealed an AUC of 0.744 [95% confidence interval (CI), 0.572–0.916], with a sensitivity of 98.8%, a specificity of 50%, a positive predictive value (PPV) of 92.4%, and a negative predictive value (NPV) of 87.5%. The segment-based analysis revealed an AUC of 0.915 (95% CI, 0.847–0.982), with a sensitivity of 93.5%, a specificity of 95%, a PPV of 77.6%, and an NPV of 98.7%. The vessel-based analysis revealed an AUC of 0.887 (95% CI, 0.808–0.966), with a sensitivity of 94.3%, a specificity of 87.3%, a PPV of 82.7%, and an NPV of 95.9%. Conclusion 256-Row CTA is a highly sensitive test of CAD and has a high predictive value. 256-Row CTA may be a potential alternative to detect coronary artery stenosis and rule out CAD in suspected patients.
ISSN:0195-668X
1522-9645
DOI:10.1093/eurheartj/ehq072