Sensitive in vivo assay of the phenylalanine hydroxylating system with a small intravenous dose of heptadeutero l-phenylalanine using high pressure liquid chromatography and capillary gas chromatography/mass fragmentography
A method is described which allows the in vivo determination of the phenylalanine hydroxylating system in atypical and classical phenylketonuria. Phenylalanine- d 7 is administered i.v. (0.030 g/kg body weight) within 10 min. Tyrosine- d 6 in plasma is measured from 30 to 240 min post load by using...
Gespeichert in:
Veröffentlicht in: | Clinica chimica acta 1979-12, Vol.99 (3), p.211-220 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A method is described which allows the in vivo determination of the phenylalanine hydroxylating system in atypical and classical phenylketonuria. Phenylalanine-
d
7 is administered i.v. (0.030 g/kg body weight) within 10 min. Tyrosine-
d
6 in plasma is measured from 30 to 240 min post load by using a computerized capillary gas chromatography/mass fragmentography system. In two patients with hyperphenylalaninemia, the residual activity of the phenylalanine hydroxylating system was 15.7 and 3.7% of the normal, in two phenylketonurics 1.5 and 0.3% respectively. The in vivo figures correspond well to the in vitro assay of the residual activity of the phenylalanine hydroxylase in needle liver biopsy material. |
---|---|
ISSN: | 0009-8981 1873-3492 |
DOI: | 10.1016/0009-8981(79)90264-X |