Sensitive in vivo assay of the phenylalanine hydroxylating system with a small intravenous dose of heptadeutero l-phenylalanine using high pressure liquid chromatography and capillary gas chromatography/mass fragmentography

A method is described which allows the in vivo determination of the phenylalanine hydroxylating system in atypical and classical phenylketonuria. Phenylalanine- d 7 is administered i.v. (0.030 g/kg body weight) within 10 min. Tyrosine- d 6 in plasma is measured from 30 to 240 min post load by using...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinica chimica acta 1979-12, Vol.99 (3), p.211-220
Hauptverfasser: Trefz, Friedrich K., Erlenmaier, Theo, Hunneman, Donald H., Bartholomé, Klaus, Lutz, Peter
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A method is described which allows the in vivo determination of the phenylalanine hydroxylating system in atypical and classical phenylketonuria. Phenylalanine- d 7 is administered i.v. (0.030 g/kg body weight) within 10 min. Tyrosine- d 6 in plasma is measured from 30 to 240 min post load by using a computerized capillary gas chromatography/mass fragmentography system. In two patients with hyperphenylalaninemia, the residual activity of the phenylalanine hydroxylating system was 15.7 and 3.7% of the normal, in two phenylketonurics 1.5 and 0.3% respectively. The in vivo figures correspond well to the in vitro assay of the residual activity of the phenylalanine hydroxylase in needle liver biopsy material.
ISSN:0009-8981
1873-3492
DOI:10.1016/0009-8981(79)90264-X