Lead and cadmium contamination during acid preservation of [drinking] water samples
Discrepancies between lead and cadmium levels in drinking water samples obtained in two surveys in Massachusetts have been investigated. The most obvious difference in the two sampling techniques was the acidification procedure, and tests were carried out to determine whether acid ampoules used in t...
Gespeichert in:
Veröffentlicht in: | Bulletin of environmental contamination and toxicology 1979-01, Vol.23 (1/2), p.107-111 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Discrepancies between lead and cadmium levels in drinking water samples obtained in two surveys in Massachusetts have been investigated. The most obvious difference in the two sampling techniques was the acidification procedure, and tests were carried out to determine whether acid ampoules used in the second sampling caused contamination. The line marking the break-off point of the acid-containing ampoules consisted of a paint containing both lead and cadmium. |
---|---|
ISSN: | 0007-4861 1432-0800 |