Repair of Interrupted Aortic Arch and Aortopulmonary Window in an Infant

The diagnosis and repair in infancy of interrupted aortic arch and aortopulmonary window is described. Using deep hypothermia and circulatory arrest, aortic continuity was established with a prosthetic graft, which was anastomosed to the aortic orifice of the aortopulmonary window. The pulmonary art...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 1979-09, Vol.28 (3), p.290-294
Hauptverfasser: Jacobson, John G., Trusler, George A., Izukawa, Teruo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The diagnosis and repair in infancy of interrupted aortic arch and aortopulmonary window is described. Using deep hypothermia and circulatory arrest, aortic continuity was established with a prosthetic graft, which was anastomosed to the aortic orifice of the aortopulmonary window. The pulmonary artery side of the aortopulmonary window was closed directly. Postoperative cardiac catheterization demonstrated a good reconstruction. Previous experience with this rare variety of interrupted aortic arch complex is reviewed.
ISSN:0003-4975
1552-6259
DOI:10.1016/S0003-4975(10)63122-0