Cardiac output response to extreme hemodilution with hemoglobin solutions of various P50 values

Cardiovascular responses have been studied in baboons, after total exchange transfusion with hemoglobin solutions having various P50 values. At the end of the exchange transfusion, the hematocrit was 1.5%, the mean hemoglobin concentration was 4.4 g/dl, and the P50 varied between 12 and 26 mm Hg. Ca...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Critical care medicine 1979-09, Vol.7 (9), p.380-384
Hauptverfasser: ROSEN, ARTHUR L, GOULD, STEVEN, SEHGAL, LAKSHMAN R, NOUD, GEORGE, SEHGAL, HANSA L, RICE, CHARLES L, MOSS, GERALD S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Cardiovascular responses have been studied in baboons, after total exchange transfusion with hemoglobin solutions having various P50 values. At the end of the exchange transfusion, the hematocrit was 1.5%, the mean hemoglobin concentration was 4.4 g/dl, and the P50 varied between 12 and 26 mm Hg. Cardiac output did not change during the study, although heart rate increased, and stroke volume and MAP decreased. Hemoglobin concentration, per se, does not appear to be the critical stimulus for an increase in cardiac output with hemoglobin solution. In addition, the position of the hemoglobin-oxygen dissociation curve does not appear to influence these hemodynamic responses. The physiological response to anemia in the presence of hemoglobin solution appears different from that observed in the absence of plasma O2 carriers.
ISSN:0090-3493
1530-0293
DOI:10.1097/00003246-197909000-00006