Packing size and shape effects on forced convection in large rectangular packed ducts with asymmetric heating
An experimental and numerical investigation of fully developed forced convection in large rectangular packed ducts is presented. The horizontally oriented ducts have the length-to-separation distance ratio of L/H=16 with two aspect ratios of W/H=8 and 4. A constant heat flux is supplied to the top w...
Gespeichert in:
Veröffentlicht in: | International journal of heat and mass transfer 1999-09, Vol.42 (17), p.3267-3277 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An experimental and numerical investigation of fully developed forced convection in large rectangular packed ducts is presented. The horizontally oriented ducts have the length-to-separation distance ratio of
L/H=16 with two aspect ratios of
W/H=8 and 4. A constant heat flux is supplied to the top wall, while the bottom and side walls are insulated. Packing of hard polyvinyl chloride Raschig rings with outside diameters of 48 and 34 mm, and expanded polystyrene spheres with diameters of 48, 38 and 29 mm are used in the air flow passage. The experiments are carried out for 200 |
---|---|
ISSN: | 0017-9310 1879-2189 |