Measurements of Characteristics of Evaporating Sprays
An experimental study was carried out to verify the feasibility of a quantitative analysis of fuel droplet diameter at high pressures and temperatures in combustion systems. A fueling system was developed to atomize fuel into droplets of the same diameter. Using this system, fueling was made into a...
Gespeichert in:
Veröffentlicht in: | JSME international journal. Series B, Fluids and thermal engineering Fluids and thermal engineering, 2000, Vol.43 (1), p.46-51 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An experimental study was carried out to verify the feasibility of a quantitative analysis of fuel droplet diameter at high pressures and temperatures in combustion systems. A fueling system was developed to atomize fuel into droplets of the same diameter. Using this system, fueling was made into a visualized device where high pressure and temperature nitrogen flowed under steady-state conditions. The laser induced fluorescence method was utilized to determine n-dodecane fuel and iso-octanefuel droplet behavior and the phase Doppler particle analyzer was used to measure the diameter and velocity of the droplets. As a result, it was confirmed that a quantitative analysis of fuel droplets is possible. The results indicate that due to its lower boiling point, iso-octane droplets tend to evaporate much faster the n-dodecane droplets. |
---|---|
ISSN: | 1340-8054 1347-5371 |
DOI: | 10.1299/jsmeb.43.46 |