Heat transfer and heat transfer fouling in Kraft black liquor evaporators

A large number of experiments have been performed with New Zealand Forest Products Kraft black liquor to measure heat transfer coefficients and fouling rates during convective and subcooled flow boiling heat transfer as a function of surface temperature, bulk temperature, velocity, and solids concen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Experimental thermal and fluid science 1997-05, Vol.14 (4), p.425-437
Hauptverfasser: Müller-Steinhagen, H., Branch, C.A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A large number of experiments have been performed with New Zealand Forest Products Kraft black liquor to measure heat transfer coefficients and fouling rates during convective and subcooled flow boiling heat transfer as a function of surface temperature, bulk temperature, velocity, and solids concentration. Results from experiments with two chemical fouling inhibitors, with Teflon surface coating and in plate and frame heat exchangers, also are presented. The fouling deposits are analyzed with respect to appearance, composition, and process conditions for which they were obtained. With the assumption of chemical reaction-controlled fouling, a deposition model is developed and compared with the experimental data.
ISSN:0894-1777
1879-2286