Two-phase pressure drop of refrigerants during flow boiling in small channels: an experimental investigation and correlation development
Two-phase flow pressure drop measurements were made during a phase-change heat transfer process with three refrigerants (R-134a, R-12, and R-113) at six different pressures ranging from 138 to 856 kPa, and in two sizes of round tubes (2.46 and 2.92 mm inside diameters) and one rectangular channel (4...
Gespeichert in:
Veröffentlicht in: | International journal of multiphase flow 2000-11, Vol.26 (11), p.1739-1754 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Two-phase flow pressure drop measurements were made during a phase-change heat transfer process with three refrigerants (R-134a, R-12, and R-113) at six different pressures ranging from 138 to 856 kPa, and in two sizes of round tubes (2.46 and 2.92 mm inside diameters) and one rectangular channel (4.06 × 1.7 mm). The data were compared with those from large tubes under similar conditions, and state-of-the-art correlations were evaluated using the R-134a data. The state-of-the-art large-tube correlations failed to satisfactorily predict the experimental data. The data were used to develop a new correlation for two-phase pressure drop during flow boiling in small channels. The correlation was then tested against the experimental data for the three refrigerants; the error was ±20%. |
---|---|
ISSN: | 0301-9322 1879-3533 |
DOI: | 10.1016/S0301-9322(99)00119-6 |