Primary dentin etching time, bond strength and ultra-structure characterization of dentin surfaces
Abstract Objectives To evaluate the effect of shortening the etching time on roughness, microhardness and bond strength of three adhesive systems to primary tooth dentin. Methods Flat dentin surfaces from primary molars were randomly assigned to six experimental groups. Three different adhesive syst...
Gespeichert in:
Veröffentlicht in: | Journal of dentistry 2010-03, Vol.38 (3), p.222-231 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract Objectives To evaluate the effect of shortening the etching time on roughness, microhardness and bond strength of three adhesive systems to primary tooth dentin. Methods Flat dentin surfaces from primary molars were randomly assigned to six experimental groups. Three different adhesive systems were used: an etch-and-rinse adhesive (Single Bond), a two-step self-etching (Clearfil SE Bond), and a one-step self-etching (One-Up Bond F) adhesive. In half of the specimens, the recommended etching time was used, in the other half the etching time was 50% reduced. After applying the adhesive, resin composite build-ups were constructed and stored in a humid environment for 24 h at 37 °C. Specimens were sectioned into 1 mm2 beams and tested for microtensile bond strength (MTBS). Debonded surfaces were analyzed by scanning electron microscopy (SEM). Additional surfaces were conditioned for microhardness measurements (KHN) and for atomic force microscopy (AFM) analysis. Intertubular and total surface roughness (Ra) were recorded. Results were analyzed with ANOVA and Student–Newman–Keuls tests ( P < 0.05). Results Single Bond and Clearfil SE Bond showed higher MTBS than One-Up Bond F. Bond strength and intertubular roughness increased when Single Bond and One-Up Bond F were used with a reduced etching time. For Clearfil SE Bond no differences in MTBS were detected when reducing the etching time. The application of phosphoric acid, Clearfil SE Bond primer and One-Up Bond F decreases dentin microhardness. Conclusions Shortening One-Up Bond F application time and reducing the etching time of phosphoric acid to one-half of the manufacturer's recommended etching time when using Single Bond are recommended when bonding to primary dentin. |
---|---|
ISSN: | 0300-5712 1879-176X |
DOI: | 10.1016/j.jdent.2009.11.001 |