Steam generator chemical cleaning at Oconee Nuclear Station
For several years, Oconee Nuclear Station Unit 1 and Unit 2 have experienced increasing pressure drop in the tube bundle of the once-through steam generators (OTSGs). Duke Power Company chemically cleaned the Unit 1 OTSGs. The cleaning reduced the OTSG pressure drop to as-new values, and the unit wa...
Gespeichert in:
Veröffentlicht in: | Nuclear plant journal 1988-09, Vol.6 (5), p.76-81 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | For several years, Oconee Nuclear Station Unit 1 and Unit 2 have experienced increasing pressure drop in the tube bundle of the once-through steam generators (OTSGs). Duke Power Company chemically cleaned the Unit 1 OTSGs. The cleaning reduced the OTSG pressure drop to as-new values, and the unit was returned to full power operation. |
---|---|
ISSN: | 0892-2055 |