Elastomeric impression materials: Effect of bulk on accuracy

Impression trays were fabricated providing 2, 4, and 6 mm spaces to determine the stability and accuracy of nine elastomeric impression materials on a simulated full crown preparation steel die. The interface space of 2 mm produced the most accurate impressions for all of the materials tested. All i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of prosthetic dentistry 1979-03, Vol.41 (3), p.304-307
Hauptverfasser: Eames, W.B., Sieweke, J.C., Wallace, S.W., Rogers, L.B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Impression trays were fabricated providing 2, 4, and 6 mm spaces to determine the stability and accuracy of nine elastomeric impression materials on a simulated full crown preparation steel die. The interface space of 2 mm produced the most accurate impressions for all of the materials tested. All impression materials except one fell within the revised American Dental Association Specifications. The clinical-type tests, using castings on dies poured from these materials, corroborated the acceptance of those materials and techniques exhibiting the least dimensional change.
ISSN:0022-3913
1097-6841
DOI:10.1016/0022-3913(79)90013-1