Skylight dome-well system analysis from intensity distribution data

A skylight test facility is in operation on the roof of the engineering building at the University of New Hampshire. Intensity distribution data for 18 skylight dome-well combinations have been taken for clear and overcast skies and a wide range of solar altitudes. These data are used in two ways: t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lighting research & technology (1969) 1989-09, Vol.21 (3), p.111-123
Hauptverfasser: Parent, M.D., Murdoch, J.B.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A skylight test facility is in operation on the roof of the engineering building at the University of New Hampshire. Intensity distribution data for 18 skylight dome-well combinations have been taken for clear and overcast skies and a wide range of solar altitudes. These data are used in two ways: to calculate coefficients of utilisation for skylight systems so that these systems may be treated in the same manner as ceiling-mounted electric luminaires; and to compare skylight systems on the basis of dome transmittance, dome diffusion, dome height-to-width ratio, well reflectance, well angle, well height-to-width ratio, and direct sun shielding.
ISSN:1477-1535
0024-3426
1477-0938
DOI:10.1177/096032718902100304