Skylight dome-well system analysis from intensity distribution data
A skylight test facility is in operation on the roof of the engineering building at the University of New Hampshire. Intensity distribution data for 18 skylight dome-well combinations have been taken for clear and overcast skies and a wide range of solar altitudes. These data are used in two ways: t...
Gespeichert in:
Veröffentlicht in: | Lighting research & technology (1969) 1989-09, Vol.21 (3), p.111-123 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A skylight test facility is in operation on the roof of the engineering building at the University of New Hampshire. Intensity distribution data for 18 skylight dome-well combinations have been taken for clear and overcast skies and a wide range of solar altitudes. These data are used in two ways: to calculate coefficients of utilisation for skylight systems so that these systems may be treated in the same manner as ceiling-mounted electric luminaires; and to compare skylight systems on the basis of dome transmittance, dome diffusion, dome height-to-width ratio, well reflectance, well angle, well height-to-width ratio, and direct sun shielding. |
---|---|
ISSN: | 1477-1535 0024-3426 1477-0938 |