Strength Variability of Inserts in Sandwich Panels
Bonded inserts are commonly used to introduce localized loads into sandwich panels. This article investigates sources of variability in the pull-out strength of metallic inserts in aramid honeycomb sandwich panels. Finite element modeling is used to investigate the sensitivity of core stresses to po...
Gespeichert in:
Veröffentlicht in: | The journal of sandwich structures & materials 2009-11, Vol.11 (6), p.501-517 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Bonded inserts are commonly used to introduce localized loads into sandwich panels. This article investigates sources of variability in the pull-out strength of metallic inserts in aramid honeycomb sandwich panels. Finite element modeling is used to investigate the sensitivity of core stresses to potting depth in partially potted inserts, which is found to be significant. Experimental specimens showed large variations in potting radii and cell wall dimensions, both critical parameters since the failure mode is predominantly core shear, adjacent to the potting. Foam core specimens were also tested and showed significantly lower variability in pull-out strength compared with honeycomb specimens. |
---|---|
ISSN: | 1099-6362 1530-7972 |
DOI: | 10.1177/1099636209104524 |