Structural analysis of two King-post timber trusses: Non-destructive evaluation and load-carrying tests
The misunderstanding of the overall behaviour of traditional timber trusses can result in incorrect strengthening interventions or, frequently, on their replacement. Timber roof structures need a more concise knowledge of the real behaviour to determine internal loads and control the load transfer....
Gespeichert in:
Veröffentlicht in: | Construction & building materials 2010-03, Vol.24 (3), p.371-383 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The misunderstanding of the overall behaviour of traditional timber trusses can result in incorrect strengthening interventions or, frequently, on their replacement. Timber roof structures need a more concise knowledge of the real behaviour to determine internal loads and control the load transfer. For that, laboratory tests on scaled or full-scale specimens of members, connections and trusses are needed.
In this paper, an accurate geometric and mechanical evaluation of the timber elements of two King-post timber trusses, based on grading results with data gathered from non-destructive tests (NDT), including mechanical evaluation of the modulus of elasticity in bending (MoE), followed by full-scale carrying tests were performed. The trusses were reassembled in laboratory and submitted to a series of symmetric and non-symmetric cyclic tests, according to the Limit States. Strengthening techniques evaluated in precedent research steps were used in a second phase of the load-carrying tests. |
---|---|
ISSN: | 0950-0618 1879-0526 |
DOI: | 10.1016/j.conbuildmat.2009.08.025 |