Quantification of 4-aminopyridine in plasma by capillary electrophoresis with electrokinetic injection
A rapid and sensitive CE method for the determination of 4-aminopyridine in human plasma using 3,4-diaminopyridine as an internal standard was developed and validated. The analytes were extracted from 0.5-mL aliquots of human plasma by liquid–liquid extraction, using 8 mL of ethyl ether, and injecte...
Gespeichert in:
Veröffentlicht in: | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2010-02, Vol.878 (3), p.290-294 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A rapid and sensitive CE method for the determination of 4-aminopyridine in human plasma using 3,4-diaminopyridine as an internal standard was developed and validated. The analytes were extracted from 0.5-mL aliquots of human plasma by liquid–liquid extraction, using 8
mL of ethyl ether, and injected electrokinetically into capillary electrophoresis equipment. The instrumental conditions were obtained and optimized by Design of Experiments (DOE – factorial and response surface model), having as factors: separation voltage, ionic strength (buffer concentration), pH and temperature. The response variables were migration time, resolution, tailing factor and drug peak area. After obtaining mathematically predicted values for the response variables with best factors combinations, these were reproduced experimentally in good agreement with predicted values. In addition to optimal separation conditions obtained by Design of Experiments, sensitivity was improved using electrokinetic injection at 10
kV for 10
s, and a capillary with 50
cm effective length and 100
μm I.D. The final instrumental conditions were voltage at 19
kV, capillary temperature at 15
°C, wavelength at 254
nm, and phosphate buffer 100
mM, pH 2.5 as the background electrolyte. This assay was linear over a concentration range of 2.5–80
ng/mL with a lower limit of quantification of 2.5
ng/mL. The relative standard deviation for the assay precision was 95%. This method was successfully applied to the quantification of 4-aminopyridine (4-AP) in plasma samples from patients with spinal cord injury. |
---|---|
ISSN: | 1570-0232 1873-376X |