Recovery from end-stage ischemic cardiomyopathy during long-term LVAD support

A patient with ischemic cardiomyopathy and extremely reduced left ventricular function (left ventricular ejection fraction = 0.10) presented to our institution for cardiac transplantation. Because of his worsening condition he was placed on the Novacor left ventricular assist device. During 3 months...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 1998-08, Vol.66 (2), p.555-557
Hauptverfasser: Pietsch, Lars, Laube, Horst, Baumann, Gerd, Konertz, Wolfgang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A patient with ischemic cardiomyopathy and extremely reduced left ventricular function (left ventricular ejection fraction = 0.10) presented to our institution for cardiac transplantation. Because of his worsening condition he was placed on the Novacor left ventricular assist device. During 3 months of support his left ventricular function recovered and he successfully underwent percutaneous transluminal coronary angioplasty and minimally invasive direct coronary artery bypass grafting procedures; subsequently he could be weaned from the left ventricular assist device and discharged. The patient is no longer considered for cardiac transplantation.
ISSN:0003-4975
1552-6259
DOI:10.1016/S0003-4975(98)00507-4