Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis
To describe and evaluate a refraction-derived method and a clinically derived method to calculate the correct corneal power for intraocular lens (IOL) power calculations after laser in situ keratomileusis (LASIK) and to compare the results to the commonly used history-derived method. Interventional...
Gespeichert in:
Veröffentlicht in: | American journal of ophthalmology 2003-09, Vol.136 (3), p.426-432 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To describe and evaluate a refraction-derived method and a clinically derived method to calculate the correct corneal power for intraocular lens (IOL) power calculations after laser in situ keratomileusis (LASIK) and to compare the results to the commonly used history-derived method.
Interventional case series.
Retrospective analysis of consecutive cases from clinical practice. Two hundred randomly selected eyes from 200 patients were evaluated before and after LASIK surgery. For each patient, we established the pre-LASIK and post-LASIK spectacle refraction, the pre-LASIK (Kpre) and post-LASIK K readings (Kpost). We then calculated for each case the pre- and post-LASIK refraction at the corneal plane and the amount of correction obtained by the refractive surgery (CRc). The cases were divided into two groups. Group I was used to derive the two formulas. The K values were calculated using the history-derived method (Kc.hd) in which Kc.hd = Kpre – CRc. Kc.hd was compared with Kpost. The average difference was 0.23 diopters for every diopter of myopia corrected. This value was used to calculate the corneal power using the refraction-derived method (Kc.rd) where Kc.rd = Kpost –0.23CRc. A regression equation was used to develop a clinically derived method (Kc.cd) where Kc.cd = 1.14Kpost –6.8. The values obtained with the two methods were compared with the Kc.hd values in group II to validate the results.
Both Kc.rd and Kc.cd values correlated highly with Kc.hd when plotted on a scattergram (
P < .001), and there was no statistically significant difference between the mean keratometric values (
P > .5).
The corneal power measurements for intraocular lens power calculations after LASIK need to be corrected to avoid hypermetropia after cataract surgery by either the history-derived method, the refraction-derived method, or the clinically derived method. |
---|---|
ISSN: | 0002-9394 1879-1891 |
DOI: | 10.1016/S0002-9394(03)00275-7 |