Characterization of thin-film losses with a synchronously pumped ringdown cavity

We describe the use of a synchronously pumped ringdown cavity for measuring total optical losses, absorption and scattering, in thin optical films of arbitrary thickness on transparent substrates. This technique is compared with a single-pulse ringdown cavity regime and is shown to have a superior s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Optics 2003-08, Vol.42 (22), p.4584-4589
Hauptverfasser: Vaschenko, Georgiy, Godwal, Yogesh, Menoni, Carmen S, Montcalm, Claude, Blacker, Richard, Siegfried, Daniel
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We describe the use of a synchronously pumped ringdown cavity for measuring total optical losses, absorption and scattering, in thin optical films of arbitrary thickness on transparent substrates. This technique is compared with a single-pulse ringdown cavity regime and is shown to have a superior signal-to-noise ratio and resolution. We also provide an analysis of the factors affecting the resolution of the technique. Using this ringdown cavity pumped by a conventional mode-locked Ti:sapphire laser, we experimentally detect losses of only 58 +/- 9 and 112 +/- 9 parts per million in Ta2O5 and SiO2 films, respectively. To our knowledge, these are so far the lowest losses measured in thin films on stand-alone transparent substrates.
ISSN:1559-128X
0003-6935
1539-4522
DOI:10.1364/AO.42.004584