Comparison of four methods for identification of gram-negative non-fermenters: organisms less commonly encountered in clinical specimens
Four commercial kits--Oxi/Ferm (OF), API 20E (AP), Minitek (MT), Flow N/F (NF) were evaluated, without additional tests, for identification of 105 opportunistic Gram-negative non-fermentative rods. Of correctly identified 42% of strains, with 35% as part (but not first) of a spectrum of identificati...
Gespeichert in:
Veröffentlicht in: | Medical microbiology and immunology 1981-06, Vol.169 (3), p.163-168 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Four commercial kits--Oxi/Ferm (OF), API 20E (AP), Minitek (MT), Flow N/F (NF) were evaluated, without additional tests, for identification of 105 opportunistic Gram-negative non-fermentative rods. Of correctly identified 42% of strains, with 35% as part (but not first) of a spectrum of identifications (SI) and 23% incorrect identification. MT yielded 75% correct identification, with 12% SI and 13% incorrect. AP correctly identified 64% of strains, with 26% SI, 10% incorrect. NF correctly speciated 70% of strains, with 24% SI, 6% incorrect. All 4 methods show deficiencies in identification of these rare but increasingly clinically encountered organisms. Addition of new tests/modification of existing ones would render these systems more capable of identifying this organisms group. |
---|---|
ISSN: | 0300-8584 1432-1831 |
DOI: | 10.1007/BF02123589 |