Effect of positional change and inhalant anesthesia on parameters of acoustic reflectometry

Objective: Purpose of this study was to find out the effect of positional change and inhalant anesthesia on acoustic reflectometry (AR) parameters (reflectivity and curve angle). Method: AR parameters were measured on 58 ears with otitis media in sitting position before anesthesia and in supine posi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of pediatric otorhinolaryngology 2003-09, Vol.67 (9), p.943-946
Hauptverfasser: Uğur, M.B., Kemaloğlu, Yusuf K., Ceylan, A., Boynueğri, S., Babacan, A., Gŏksu, N.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective: Purpose of this study was to find out the effect of positional change and inhalant anesthesia on acoustic reflectometry (AR) parameters (reflectivity and curve angle). Method: AR parameters were measured on 58 ears with otitis media in sitting position before anesthesia and in supine position under inhalant anesthesia, subsequently. Results: Under anesthesia, ears with effusion disclosed more changes in reflectivity (Chi-squared analysis, χ 2-test; P0.1) than those without effusion. Further, inhalant anesthesia caused more changes in the false negative ears (63.63%) than in those with effusion having positive test before anesthesia (12.90%) ( P
ISSN:0165-5876
1872-8464
DOI:10.1016/S0165-5876(03)00159-9