Diode-laser-based high-precision absolute distance interferometer of 20 m range

We present a hybrid absolute distance measurement method that is based on a combination of frequency sweeping, variable synthetic, and two-wavelength, fixed synthetic wavelength interferometry. Both experiments were realized by two external cavity diode lasers. The measurement uncertainty was experi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Optics 2009-11, Vol.48 (32), p.6188-6194
Hauptverfasser: Pollinger, Florian, Meiners-Hagen, Karl, Wedde, Martin, Abou-Zeid, Ahmed
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 6194
container_issue 32
container_start_page 6188
container_title Applied Optics
container_volume 48
creator Pollinger, Florian
Meiners-Hagen, Karl
Wedde, Martin
Abou-Zeid, Ahmed
description We present a hybrid absolute distance measurement method that is based on a combination of frequency sweeping, variable synthetic, and two-wavelength, fixed synthetic wavelength interferometry. Both experiments were realized by two external cavity diode lasers. The measurement uncertainty was experimentally and theoretically demonstrated to be smaller than 12 microm at a measurement distance of 20 m.
doi_str_mv 10.1364/ao.48.006188
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_734133696</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>734133696</sourcerecordid><originalsourceid>FETCH-LOGICAL-c286t-1f5ffba0c16fdde7ddbc197902bb1676ea1ca2ce1e590b12e6b4da808bf917083</originalsourceid><addsrcrecordid>eNpFkDtPwzAUhS0EoqWwMaNsLKT4xrETj1V5SpW6wGz5cd0GJXGxk4F_T1ArsZx7rvTpDB8ht0CXwET5qMOyrJeUCqjrMzIvgPOcgeDnZE4pZbmQjM_IVUpf08dLWV2SGUhJSwZ8TrZPTXCYtzphzM2ULts3u31-iGib1IQ-0yaFdhwwc00adG8xa_oBo8cYOpxKFnxW0KzLou53eE0uvG4T3pzugny-PH-s3_LN9vV9vdrktqjFkIPn3htNLQjvHFbOGQuykrQwBkQlUIPVhUVALqmBAoUpna5pbbyEitZsQe6Pu4cYvkdMg-qaZLFtdY9hTKpiJTAmpJjIhyNpY0gpoleH2HQ6_iig6s-gWm1VWaujwQm_Ow2PpkP3D5-UsV9pv2xK</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>734133696</pqid></control><display><type>article</type><title>Diode-laser-based high-precision absolute distance interferometer of 20 m range</title><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>Pollinger, Florian ; Meiners-Hagen, Karl ; Wedde, Martin ; Abou-Zeid, Ahmed</creator><creatorcontrib>Pollinger, Florian ; Meiners-Hagen, Karl ; Wedde, Martin ; Abou-Zeid, Ahmed</creatorcontrib><description>We present a hybrid absolute distance measurement method that is based on a combination of frequency sweeping, variable synthetic, and two-wavelength, fixed synthetic wavelength interferometry. Both experiments were realized by two external cavity diode lasers. The measurement uncertainty was experimentally and theoretically demonstrated to be smaller than 12 microm at a measurement distance of 20 m.</description><identifier>ISSN: 0003-6935</identifier><identifier>EISSN: 2155-3165</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/ao.48.006188</identifier><identifier>PMID: 19904315</identifier><language>eng</language><publisher>United States</publisher><ispartof>Applied Optics, 2009-11, Vol.48 (32), p.6188-6194</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c286t-1f5ffba0c16fdde7ddbc197902bb1676ea1ca2ce1e590b12e6b4da808bf917083</citedby><cites>FETCH-LOGICAL-c286t-1f5ffba0c16fdde7ddbc197902bb1676ea1ca2ce1e590b12e6b4da808bf917083</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19904315$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pollinger, Florian</creatorcontrib><creatorcontrib>Meiners-Hagen, Karl</creatorcontrib><creatorcontrib>Wedde, Martin</creatorcontrib><creatorcontrib>Abou-Zeid, Ahmed</creatorcontrib><title>Diode-laser-based high-precision absolute distance interferometer of 20 m range</title><title>Applied Optics</title><addtitle>Appl Opt</addtitle><description>We present a hybrid absolute distance measurement method that is based on a combination of frequency sweeping, variable synthetic, and two-wavelength, fixed synthetic wavelength interferometry. Both experiments were realized by two external cavity diode lasers. The measurement uncertainty was experimentally and theoretically demonstrated to be smaller than 12 microm at a measurement distance of 20 m.</description><issn>0003-6935</issn><issn>2155-3165</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNpFkDtPwzAUhS0EoqWwMaNsLKT4xrETj1V5SpW6wGz5cd0GJXGxk4F_T1ArsZx7rvTpDB8ht0CXwET5qMOyrJeUCqjrMzIvgPOcgeDnZE4pZbmQjM_IVUpf08dLWV2SGUhJSwZ8TrZPTXCYtzphzM2ULts3u31-iGib1IQ-0yaFdhwwc00adG8xa_oBo8cYOpxKFnxW0KzLou53eE0uvG4T3pzugny-PH-s3_LN9vV9vdrktqjFkIPn3htNLQjvHFbOGQuykrQwBkQlUIPVhUVALqmBAoUpna5pbbyEitZsQe6Pu4cYvkdMg-qaZLFtdY9hTKpiJTAmpJjIhyNpY0gpoleH2HQ6_iig6s-gWm1VWaujwQm_Ow2PpkP3D5-UsV9pv2xK</recordid><startdate>20091110</startdate><enddate>20091110</enddate><creator>Pollinger, Florian</creator><creator>Meiners-Hagen, Karl</creator><creator>Wedde, Martin</creator><creator>Abou-Zeid, Ahmed</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20091110</creationdate><title>Diode-laser-based high-precision absolute distance interferometer of 20 m range</title><author>Pollinger, Florian ; Meiners-Hagen, Karl ; Wedde, Martin ; Abou-Zeid, Ahmed</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c286t-1f5ffba0c16fdde7ddbc197902bb1676ea1ca2ce1e590b12e6b4da808bf917083</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pollinger, Florian</creatorcontrib><creatorcontrib>Meiners-Hagen, Karl</creatorcontrib><creatorcontrib>Wedde, Martin</creatorcontrib><creatorcontrib>Abou-Zeid, Ahmed</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied Optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pollinger, Florian</au><au>Meiners-Hagen, Karl</au><au>Wedde, Martin</au><au>Abou-Zeid, Ahmed</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Diode-laser-based high-precision absolute distance interferometer of 20 m range</atitle><jtitle>Applied Optics</jtitle><addtitle>Appl Opt</addtitle><date>2009-11-10</date><risdate>2009</risdate><volume>48</volume><issue>32</issue><spage>6188</spage><epage>6194</epage><pages>6188-6194</pages><issn>0003-6935</issn><eissn>2155-3165</eissn><eissn>1539-4522</eissn><abstract>We present a hybrid absolute distance measurement method that is based on a combination of frequency sweeping, variable synthetic, and two-wavelength, fixed synthetic wavelength interferometry. Both experiments were realized by two external cavity diode lasers. The measurement uncertainty was experimentally and theoretically demonstrated to be smaller than 12 microm at a measurement distance of 20 m.</abstract><cop>United States</cop><pmid>19904315</pmid><doi>10.1364/ao.48.006188</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-6935
ispartof Applied Optics, 2009-11, Vol.48 (32), p.6188-6194
issn 0003-6935
2155-3165
1539-4522
language eng
recordid cdi_proquest_miscellaneous_734133696
source Alma/SFX Local Collection; Optica Publishing Group Journals
title Diode-laser-based high-precision absolute distance interferometer of 20 m range
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T22%3A59%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Diode-laser-based%20high-precision%20absolute%20distance%20interferometer%20of%2020%20m%20range&rft.jtitle=Applied%20Optics&rft.au=Pollinger,%20Florian&rft.date=2009-11-10&rft.volume=48&rft.issue=32&rft.spage=6188&rft.epage=6194&rft.pages=6188-6194&rft.issn=0003-6935&rft.eissn=2155-3165&rft_id=info:doi/10.1364/ao.48.006188&rft_dat=%3Cproquest_cross%3E734133696%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=734133696&rft_id=info:pmid/19904315&rfr_iscdi=true