Influence of curing protocol on selected properties of light-curing polymers: Degree of conversion, volume contraction, elastic modulus, and glass transition temperature
Abstract Objectives The purpose of this study was to investigate the effect of light-curing protocol on degree of conversion (DC), volume contraction ( C ), elastic modulus ( E ), and glass transition temperature ( Tg ) as measured on a model polymer. It was a further aim to correlate the measured v...
Gespeichert in:
Veröffentlicht in: | Dental materials 2009-12, Vol.25 (12), p.1576-1584 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract Objectives The purpose of this study was to investigate the effect of light-curing protocol on degree of conversion (DC), volume contraction ( C ), elastic modulus ( E ), and glass transition temperature ( Tg ) as measured on a model polymer. It was a further aim to correlate the measured values with each other. Methods Different light-curing protocols were used in order to investigate the influence of energy density (ED), power density (PD), and mode of cure on the properties. The modes of cure were continuous, pulse-delay, and stepped irradiation. DC was measured by Raman micro-spectroscopy. C was determined by pycnometry and a density column. E was measured by a dynamic mechanical analyzer (DMA), and Tg was measured by differential scanning calorimetry (DSC). Data were submitted to two- and three-way ANOVA, and linear regression analyses. Results ED, PD, and mode of cure influenced DC, C , E , and Tg of the polymer. A significant positive correlation was found between ED and DC ( r = 0.58), ED and E ( r = 0.51), and ED and Tg ( r = 0.44). Taken together, ED and PD were significantly related to DC and E . The regression coefficient was positive for ED and negative for PD. Significant positive correlations were detected between DC and C ( r = 0.54), DC and E ( r = 0.61), and DC and Tg ( r = 0.53). Comparisons between continuous and pulse-delay modes of cure showed significant influence of mode of cure: pulse-delay curing resulted in decreased DC, decreased C , and decreased Tg . Influence of mode of cure, when comparing continuous and step modes of cure, was more ambiguous. Significance A complex relationship exists between curing protocol, microstructure of the resin and the investigated properties. The overall performance of a composite is thus indirectly affected by the curing protocol adopted, and the desired reduction of C may be in fact a consequence of the decrease in DC. |
---|---|
ISSN: | 0109-5641 1879-0097 |
DOI: | 10.1016/j.dental.2009.08.001 |