Screening digital mammography: one year result for the Alpes-Maritimes region

After one year of experience with screening digital mammography, the results of this technique (n=9640) are compared to screen-film mammography (n=240 376) with double reading. Evaluation for each technique of the rate of call-back, positive results before and after work-up by the first reader and d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal de radiologie 2010-05, Vol.91 (5 Pt 1), p.549-553
Hauptverfasser: Balu-Maestro, C, Bailly, L, Granon, C, Namer, M
Format: Artikel
Sprache:fre
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:After one year of experience with screening digital mammography, the results of this technique (n=9640) are compared to screen-film mammography (n=240 376) with double reading. Evaluation for each technique of the rate of call-back, positive results before and after work-up by the first reader and distribution based on the BI-RADS classification by the ACR, rate of complementary US, detected abnormalities (microcalcifications) and detected cancers. The rate of positive mammograms was significantly higher for the digital technique (17.3% versus 15.1%) because of the first reader (16.3% versus 13.9%) whereas it was significantly lower after complementary work-up (3% versus 3.7%). The rate of BI-RADS 0 was significantly higher with digital imaging irrespective of patient age. The rate of US was higher for type 1 and 2 breasts at digital imaging (46% versus 36%, p
ISSN:0221-0363