Hamstring Donor-Site Block: Evaluation of Pain Control After Anterior Cruciate Ligament Reconstruction
Purpose The purpose of this study was to evaluate the effectiveness of using a hamstring donor-site block in controlling postoperative pain levels after anterior cruciate ligament (ACL) reconstruction with autogenous hamstring graft. Methods Over a 5-month period, 27 patients underwent ACL reconstru...
Gespeichert in:
Veröffentlicht in: | Arthroscopy 2010-07, Vol.26 (7), p.894-900 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose The purpose of this study was to evaluate the effectiveness of using a hamstring donor-site block in controlling postoperative pain levels after anterior cruciate ligament (ACL) reconstruction with autogenous hamstring graft. Methods Over a 5-month period, 27 patients underwent ACL reconstruction with hamstring autograft. All patients received a preoperative femoral nerve block. Intraoperatively, these patients were randomly assigned to groups with and without a hamstring donor-site block. The block group received a 20-mL injection of 0.25% bupivacaine into the hamstring donor site through an arthroscopic shaver sleeve. Both groups received standard postoperative pain medications as needed. Postoperative pain scores were taken by use of a visual analog scale (VAS) and recorded immediately on arrival to the recovery room, at 1 hour after arrival, and at 2 hours after arrival. Results There were 15 patients in the hamstring donor-site block group and 12 patients in the standard treatment group. For the block group, mean VAS scores were 3.20 ± 2.54 on arrival, 2.80 ± 1.61 at 1 hour, and 2.87 ± 1.41 at 2 hours. For the standard treatment group, mean VAS scores were 5.50 ± 1.62 on arrival, 6.08 ± 1.56 at 1 hour, and 5.33 ± 2.02 at 2 hours. The hamstring block group had statistically significantly lower mean VAS scores on arrival ( P = .0118), at 1 hour ( P = .0001), and at 2 hours ( P = .0010). There were no complications in either group. Conclusions Injection of the hamstring donor site with local anesthetic through an arthroscopic shaver sleeve showed a statistically significant improvement in postoperative pain levels in patients undergoing autogenous hamstring ACL reconstruction. Level of Evidence Level III, retrospective comparative study. |
---|---|
ISSN: | 0749-8063 1526-3231 |
DOI: | 10.1016/j.arthro.2009.11.022 |