Intraductal injection of the breast: a potential pitfall of radioisotope occult lesion localization

The use of radioisotope for the localization of occult breast lesions (ROLL) has been advocated in preference to wire guided excision as it allows reduced excision volume and better lesion centering. However, as this technique is new, potential complications are unknown. In 2 out of 38 ROLL procedur...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:British journal of radiology 2003-06, Vol.76 (906), p.425-426
Hauptverfasser: RAMPAUL, R. S, MACMILLAN, R. D, EVANS, A. J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The use of radioisotope for the localization of occult breast lesions (ROLL) has been advocated in preference to wire guided excision as it allows reduced excision volume and better lesion centering. However, as this technique is new, potential complications are unknown. In 2 out of 38 ROLL procedures performed at our institution, intraductal injection of isotope has occurred. This was diagnosed on check mammography as non-ionic iodinated contrast was mixed with the isotope. In one of these cases conversion to wire localization was required.
ISSN:0007-1285
1748-880X
DOI:10.1259/bjr/27639166