Endovascular Treatment of Traumatic Thoracic Aortic Injuries: Short- and Medium-term Follow-up
Background Successful thoracic endovascular aortic repair (TEVAR) with low rates of complications has been referred to in the treatment of traumatic thoracic aortic injuries; however, we still do not know the long-term behavior. In this series, short- and intermediate-term results of TEVAR of trauma...
Gespeichert in:
Veröffentlicht in: | Annals of vascular surgery 2010-02, Vol.24 (2), p.160-166 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background Successful thoracic endovascular aortic repair (TEVAR) with low rates of complications has been referred to in the treatment of traumatic thoracic aortic injuries; however, we still do not know the long-term behavior. In this series, short- and intermediate-term results of TEVAR of traumatic aortic injuries are analyzed. Methods The clinical charts and courses of 20 patients (mean age, 31.8 years; age range, 15-65 years; 14 [70%] men) with traumatic thoracic aortic injuries treated with TEVAR were retrospectively reviewed. Mean delay from trauma to intervention was 15 days (range, 0-180 days). Results The initial success rate was 100%, with no deaths or intraoperative leaks, although in 4 (20%) patients, injuries were repaired in the arterial access site. The mean postoperative follow-up was 43.53 months (range, 5.5-108.0 months). Four (20%) patients required reintervention: 2 postoperative revascularizations of the left subclavian artery (20% of the patients in whom the ostium was intentionally occluded) and 2 aortic reinterventions (endovascular treatment of a collapsed stent graft and open repair after thrombosis of another stent graft). All reinterventions were successfully performed and no additional complications were registered during follow-up. Asymptomatic findings related to the stent graft included lack of proximal device-wall apposition in 8 patients (40%), intragraft mural thrombus formation during the first 6 months in 7 patients (35%), and an asymptomatic fracture of the longitudinal reinforcing bar of the stent graft 4 years later in 1 patient (5%). Conclusion Although not completely exempt of complications, TEVAR provides a reliable method for the treatment of traumatic thoracic aortic injuries with good results in the short- and medium-term follow-up. All complications have been treated successfully. Long-term evolution of lack of proximal device-wall apposition and intragraft mural thrombus formation should be closely monitored to prevent long-term complications. |
---|---|
ISSN: | 0890-5096 1615-5947 |
DOI: | 10.1016/j.avsg.2009.05.013 |