Far-field holography of ampule contaminants
Detection and measurement of contaminating particles in cylindrical ampules have been achieved using far-field holography. The degradation of the images caused by the cylindrical nature of the ampule was overcome by index matching and clear images of particles as small as 5 microm in diameter were o...
Gespeichert in:
Veröffentlicht in: | Applied Optics 1982-07, Vol.21 (14), p.2548-2553 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Detection and measurement of contaminating particles in cylindrical ampules have been achieved using far-field holography. The degradation of the images caused by the cylindrical nature of the ampule was overcome by index matching and clear images of particles as small as 5 microm in diameter were obtained. |
---|---|
ISSN: | 1559-128X 0003-6935 1539-4522 |
DOI: | 10.1364/AO.21.002548 |