Differentiation of Pancreas Carcinoma From Healthy Pancreatic Tissue Using Multiple b-Values: Comparison of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Derived Parameters
OBJECTIVES:To evaluate in detail the diagnostic performance of diffusion-weighted imaging (DWI) to differentiate pancreas carcinoma from healthy pancreas using the apparent diffusion coefficient (ADC) and parameters derived from the intravoxel incoherent motion (IVIM) theory. MATERIALS AND METHODS:T...
Gespeichert in:
Veröffentlicht in: | Investigative radiology 2009-12, Vol.44 (12), p.769-775 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | OBJECTIVES:To evaluate in detail the diagnostic performance of diffusion-weighted imaging (DWI) to differentiate pancreas carcinoma from healthy pancreas using the apparent diffusion coefficient (ADC) and parameters derived from the intravoxel incoherent motion (IVIM) theory.
MATERIALS AND METHODS:Twenty-three patients with pancreas carcinoma and 14 volunteers with healthy pancreas were examined at 1.5 Tesla using a single-shot echo-planar imaging DWI pulse sequence. Eleven b-values ranging from 0 to 800 s/mm were used. The acquisition was separated into blocks (b0, b25), (b0, b50),...(b0, b800) and each block was acquired in a single expirational breath-hold (TA = 26 seconds) to avoid motion artifacts. The ADC was calculated for all b-values using linear regression yielding ADCtot. By applying the IVIM model, which allows for the estimation of perfusion effects in DWI, the perfusion fraction f and the perfusion free diffusion parameter D were calculated. The diagnostic performance of ADC, f and D as a measure for the differentiation between healthy pancreas and pancreatic carcinoma was evaluated with receiver operating characteristics analysis.
RESULTS:In the healthy control group, the ADCtot ranged from 1.53 to 2.01 μm/ms with a mean value of 1.71 ± 0.19 μm/ms, the perfusion fraction f ranged from 18.5% to 40.4% with a mean value of 25.0 ± 6.2%, and the diffusion coefficient D from 0.94 to 1.28 μm/ms with a mean value of 1.13 ± 0.15 μm/ms. In patients with pancreas carcinoma, the ADCtot ranged from 0.98 to 1.81 μm/ms with a mean value of 1.31 ± 0.24 μm/ms, the perfusion fraction f ranged from 0% to 20.4% with a mean value of 8.59 ± 4.6% and the diffusion coefficient D from 0.74 to 1.60 μm/ms with a mean value of 1.15 ± 0.22 μm/ms. In comparison to healthy pancreatic tissue, a significant reduction of the perfusion fraction f and of ADCtot was found in pancreatic carcinoma (P < 0.00001, 0.0002, respectively). The f value showed more than a 10-fold higher significance level in distinguishing cancerous from normal tissue when compared with the ADCtot value. No significant difference in the diffusion coefficient D was observed between the 2 groups (P > 0.5). In the receiver operating characteristic-analyses, the area under curve for f was 0.991 and significantly larger than ADCtot (P < 0.05). f had the highest sensitivity, specificity, negative predictive value, and positive predictive value with 95.7%, 100%, 93.3%, and 100%, respectively.
CONCLUSIONS:Using |
---|---|
ISSN: | 0020-9996 1536-0210 |
DOI: | 10.1097/RLI.0b013e3181b62271 |