Transcatheter closure of patent ductus arteriosus in a dog with a peripheral vascular occlusion device
A 4-month-old, intact female mixed-breed dog presented to the Purdue University Veterinary Teaching Hospital for evaluation of a cardiac murmur. A large left-to-right patent ductus arteriosus (PDA) was diagnosed and interventional correction was achieved with a commercially available peripheral vasc...
Gespeichert in:
Veröffentlicht in: | Journal of veterinary cardiology 2006-11, Vol.8 (2), p.139-143 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 143 |
---|---|
container_issue | 2 |
container_start_page | 139 |
container_title | Journal of veterinary cardiology |
container_volume | 8 |
creator | Hogan, Daniel F. Green, Henry W. Sanders, Robert A. |
description | A 4-month-old, intact female mixed-breed dog presented to the Purdue University Veterinary Teaching Hospital for evaluation of a cardiac murmur. A large left-to-right patent ductus arteriosus (PDA) was diagnosed and interventional correction was achieved with a commercially available peripheral vascular occlusion device (VOD). The VOD is composed of a nitinol wire mesh and is similar in composition and shape to a commercially available human PDA occluder, however, it can be deployed through smaller delivery catheters and is much less expensive. The product and procedural details of the device are described. |
doi_str_mv | 10.1016/j.jvc.2005.12.004 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733875791</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1760273406000312</els_id><sourcerecordid>733875791</sourcerecordid><originalsourceid>FETCH-LOGICAL-c267t-fadd9042fe78880ceba3671b48d32e8ea980cd2932e6724d0361fcb730016e653</originalsourceid><addsrcrecordid>eNp9kD1PwzAURS0EolD4ASzIG1OCP9I4EROq-JIqsZTZcuwX6iiNg-0U8e9x1UpsTH72Pe9KPgjdUJJTQsv7Lu92OmeELHLKckKKE3RBK7HISMWL0zSLkmRM8GKGLkPoCOEVI-IczWidCF6IC9SuvRqCVnEDETzWvQuTB-xaPKoIQ8Rm0nEKWPkU2xQGbAessHGf-NvGTRrHFIwb8KrHOxX01CuPndb9FKwbsIGd1XCFzlrVB7g-nnP08fy0Xr5mq_eXt-XjKtOsFDFrlTE1KVgLoqoqoqFRvBS0KSrDGVSg6vRoWJ0upWCFIbykrW4EJ0kHlAs-R3eH3tG7rwlClFsbNPS9GsBNQQrOkx9R00TSA6m9C8FDK0dvt8r_SErk3q7sZLIr93YlZTLZTTu3x_ap2YL52zjqTMDDAYD0x50FL4O2MGgw1oOO0jj7T_0vsW-L7g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733875791</pqid></control><display><type>article</type><title>Transcatheter closure of patent ductus arteriosus in a dog with a peripheral vascular occlusion device</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Hogan, Daniel F. ; Green, Henry W. ; Sanders, Robert A.</creator><creatorcontrib>Hogan, Daniel F. ; Green, Henry W. ; Sanders, Robert A.</creatorcontrib><description>A 4-month-old, intact female mixed-breed dog presented to the Purdue University Veterinary Teaching Hospital for evaluation of a cardiac murmur. A large left-to-right patent ductus arteriosus (PDA) was diagnosed and interventional correction was achieved with a commercially available peripheral vascular occlusion device (VOD). The VOD is composed of a nitinol wire mesh and is similar in composition and shape to a commercially available human PDA occluder, however, it can be deployed through smaller delivery catheters and is much less expensive. The product and procedural details of the device are described.</description><identifier>ISSN: 1760-2734</identifier><identifier>EISSN: 1875-0834</identifier><identifier>DOI: 10.1016/j.jvc.2005.12.004</identifier><identifier>PMID: 19083347</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Cardiac ; Congenital ; Interventional ; Veterinary</subject><ispartof>Journal of veterinary cardiology, 2006-11, Vol.8 (2), p.139-143</ispartof><rights>2006 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c267t-fadd9042fe78880ceba3671b48d32e8ea980cd2932e6724d0361fcb730016e653</citedby><cites>FETCH-LOGICAL-c267t-fadd9042fe78880ceba3671b48d32e8ea980cd2932e6724d0361fcb730016e653</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jvc.2005.12.004$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19083347$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hogan, Daniel F.</creatorcontrib><creatorcontrib>Green, Henry W.</creatorcontrib><creatorcontrib>Sanders, Robert A.</creatorcontrib><title>Transcatheter closure of patent ductus arteriosus in a dog with a peripheral vascular occlusion device</title><title>Journal of veterinary cardiology</title><addtitle>J Vet Cardiol</addtitle><description>A 4-month-old, intact female mixed-breed dog presented to the Purdue University Veterinary Teaching Hospital for evaluation of a cardiac murmur. A large left-to-right patent ductus arteriosus (PDA) was diagnosed and interventional correction was achieved with a commercially available peripheral vascular occlusion device (VOD). The VOD is composed of a nitinol wire mesh and is similar in composition and shape to a commercially available human PDA occluder, however, it can be deployed through smaller delivery catheters and is much less expensive. The product and procedural details of the device are described.</description><subject>Cardiac</subject><subject>Congenital</subject><subject>Interventional</subject><subject>Veterinary</subject><issn>1760-2734</issn><issn>1875-0834</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp9kD1PwzAURS0EolD4ASzIG1OCP9I4EROq-JIqsZTZcuwX6iiNg-0U8e9x1UpsTH72Pe9KPgjdUJJTQsv7Lu92OmeELHLKckKKE3RBK7HISMWL0zSLkmRM8GKGLkPoCOEVI-IczWidCF6IC9SuvRqCVnEDETzWvQuTB-xaPKoIQ8Rm0nEKWPkU2xQGbAessHGf-NvGTRrHFIwb8KrHOxX01CuPndb9FKwbsIGd1XCFzlrVB7g-nnP08fy0Xr5mq_eXt-XjKtOsFDFrlTE1KVgLoqoqoqFRvBS0KSrDGVSg6vRoWJ0upWCFIbykrW4EJ0kHlAs-R3eH3tG7rwlClFsbNPS9GsBNQQrOkx9R00TSA6m9C8FDK0dvt8r_SErk3q7sZLIr93YlZTLZTTu3x_ap2YL52zjqTMDDAYD0x50FL4O2MGgw1oOO0jj7T_0vsW-L7g</recordid><startdate>200611</startdate><enddate>200611</enddate><creator>Hogan, Daniel F.</creator><creator>Green, Henry W.</creator><creator>Sanders, Robert A.</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200611</creationdate><title>Transcatheter closure of patent ductus arteriosus in a dog with a peripheral vascular occlusion device</title><author>Hogan, Daniel F. ; Green, Henry W. ; Sanders, Robert A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c267t-fadd9042fe78880ceba3671b48d32e8ea980cd2932e6724d0361fcb730016e653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Cardiac</topic><topic>Congenital</topic><topic>Interventional</topic><topic>Veterinary</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hogan, Daniel F.</creatorcontrib><creatorcontrib>Green, Henry W.</creatorcontrib><creatorcontrib>Sanders, Robert A.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of veterinary cardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hogan, Daniel F.</au><au>Green, Henry W.</au><au>Sanders, Robert A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Transcatheter closure of patent ductus arteriosus in a dog with a peripheral vascular occlusion device</atitle><jtitle>Journal of veterinary cardiology</jtitle><addtitle>J Vet Cardiol</addtitle><date>2006-11</date><risdate>2006</risdate><volume>8</volume><issue>2</issue><spage>139</spage><epage>143</epage><pages>139-143</pages><issn>1760-2734</issn><eissn>1875-0834</eissn><abstract>A 4-month-old, intact female mixed-breed dog presented to the Purdue University Veterinary Teaching Hospital for evaluation of a cardiac murmur. A large left-to-right patent ductus arteriosus (PDA) was diagnosed and interventional correction was achieved with a commercially available peripheral vascular occlusion device (VOD). The VOD is composed of a nitinol wire mesh and is similar in composition and shape to a commercially available human PDA occluder, however, it can be deployed through smaller delivery catheters and is much less expensive. The product and procedural details of the device are described.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>19083347</pmid><doi>10.1016/j.jvc.2005.12.004</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1760-2734 |
ispartof | Journal of veterinary cardiology, 2006-11, Vol.8 (2), p.139-143 |
issn | 1760-2734 1875-0834 |
language | eng |
recordid | cdi_proquest_miscellaneous_733875791 |
source | ScienceDirect Journals (5 years ago - present) |
subjects | Cardiac Congenital Interventional Veterinary |
title | Transcatheter closure of patent ductus arteriosus in a dog with a peripheral vascular occlusion device |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T13%3A25%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Transcatheter%20closure%20of%20patent%20ductus%20arteriosus%20in%20a%20dog%20with%20a%20peripheral%20vascular%20occlusion%20device&rft.jtitle=Journal%20of%20veterinary%20cardiology&rft.au=Hogan,%20Daniel%20F.&rft.date=2006-11&rft.volume=8&rft.issue=2&rft.spage=139&rft.epage=143&rft.pages=139-143&rft.issn=1760-2734&rft.eissn=1875-0834&rft_id=info:doi/10.1016/j.jvc.2005.12.004&rft_dat=%3Cproquest_cross%3E733875791%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733875791&rft_id=info:pmid/19083347&rft_els_id=S1760273406000312&rfr_iscdi=true |