Transcatheter closure of patent ductus arteriosus in a dog with a peripheral vascular occlusion device
A 4-month-old, intact female mixed-breed dog presented to the Purdue University Veterinary Teaching Hospital for evaluation of a cardiac murmur. A large left-to-right patent ductus arteriosus (PDA) was diagnosed and interventional correction was achieved with a commercially available peripheral vasc...
Gespeichert in:
Veröffentlicht in: | Journal of veterinary cardiology 2006-11, Vol.8 (2), p.139-143 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A 4-month-old, intact female mixed-breed dog presented to the Purdue University Veterinary Teaching Hospital for evaluation of a cardiac murmur. A large left-to-right patent ductus arteriosus (PDA) was diagnosed and interventional correction was achieved with a commercially available peripheral vascular occlusion device (VOD). The VOD is composed of a nitinol wire mesh and is similar in composition and shape to a commercially available human PDA occluder, however, it can be deployed through smaller delivery catheters and is much less expensive. The product and procedural details of the device are described. |
---|---|