Estimation of the low-density lipoprotein (LDL) subclass phenotype using a direct, automated assay of small dense LDL-cholesterol without sample pretreatment
A new method (sLDL-EX “SEIKEN”) is commercially available for the direct quantification of small dense LDL-cholesterol (sd-LDL) on automated chemistry analyzers, without manual sample pretreatment. We evaluated the performance of this direct assay to estimate the small dense LDL subclass phenotype (...
Gespeichert in:
Veröffentlicht in: | Clinica chimica acta 2010-09, Vol.411 (17), p.1361-1366 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A new method (sLDL-EX “SEIKEN”) is commercially available for the direct quantification of small dense LDL-cholesterol (sd-LDL) on automated chemistry analyzers, without manual sample pretreatment. We evaluated the performance of this direct assay to estimate the small dense LDL subclass phenotype (“non-A”), defined by polyacrylamide gel tube electrophoresis.
Fasting serum samples from 189 healthy subjects (age 18–75
y, 96 females) were collected. The direct sd-LDL assay (from Randox Laboratories) was applied on a Roche Modular P analyzer. The Quantimetrix Lipoprint
TM LDL System was used to define LDL subclass phenotypes (A and non-A). ROC curve analysis was performed for sd-LDL and other lipids and apolipoproteins (apo) with respect to phenotype non-A.
sd-LDL concentrations (40.4
±
18.6
mg/dl) in the total group correlated (P
<
0.0001) with apoB (r
=
0.831), apoB/A-I ratio (r
=
0.757), non-HDL-cholesterol (r
=
0.821), triglycerides (r
=
0.439), and LDL-cholesterol (r
=
0.641). Higher sd-LDL concentrations (P
<
0.0001) were measured in subjects with LDL phenotype non-A (53.6
±
17.0
mg/dl, n
=
92) than in those with phenotype A (27.9
±
8.9
mg/dl, n
=
97). In logistic regression analysis, sd-LDL and apoA-I were independently associated with LDL subclass phenotype non-A. Highest areas under ROC curves were obtained for sd-LDL (0.943), triglycerides (0.833), triglyceride/HDL-cholesterol (0.838) and apoB/A-I ratio (0.826) to predict phenotype non-A. The sd-LDL cut-off point for optimal sensitivity (87.9%) and specificity (92.8%) was >
38.5
mg/dl.
The direct, homogeneous sd-LDL method is easily applicable on an automated chemistry analyzer and shows acceptable performance to estimate the electrophoretic LDL subclass phenotype. |
---|---|
ISSN: | 0009-8981 1873-3492 |
DOI: | 10.1016/j.cca.2010.05.038 |